Note: this bug is "hidden" by avoiding "death spiral" code path by
6228659 ("device: handle broader range of errors in RoutineReceiveIncoming").
If the code reached "death spiral" mechanism, there would be multiple
double frees happening. This results in a deadlock on iOS, because the
pools are fixed size and goroutine might stop until somebody makes
space in the pool.
This was almost 100% repro on the new ARM Macbooks:
- Build with 'ios' tag for Mac. This will enable bounded pools.
- Somehow call device.IpcSet at least couple of times (update config)
- device.BindUpdate() would be triggered
- RoutineReceiveIncoming would enter "death spiral".
- RoutineReceiveIncoming would stall on double free (pool is already
full)
- The stuck routine would deadlock 'device.closeBindLocked()' function
on line 'netc.stopping.Wait()'
Signed-off-by: Kristupas Antanavičius <kristupas.antanavicius@nordsec.com>