2019-01-02 01:55:51 +01:00
|
|
|
/* SPDX-License-Identifier: MIT
|
2018-05-03 15:04:00 +02:00
|
|
|
*
|
2020-05-02 10:08:26 +02:00
|
|
|
* Copyright (C) 2017-2020 WireGuard LLC. All Rights Reserved.
|
2018-05-03 15:04:00 +02:00
|
|
|
*/
|
|
|
|
|
2019-03-03 04:04:41 +01:00
|
|
|
package device
|
2017-06-04 21:48:15 +02:00
|
|
|
|
2017-08-22 14:57:32 +02:00
|
|
|
import (
|
|
|
|
"sync/atomic"
|
2019-05-14 09:09:52 +02:00
|
|
|
|
|
|
|
"golang.zx2c4.com/wireguard/tun"
|
2017-08-22 14:57:32 +02:00
|
|
|
)
|
2017-07-15 16:27:59 +02:00
|
|
|
|
|
|
|
const DefaultMTU = 1420
|
|
|
|
|
2017-08-22 14:57:32 +02:00
|
|
|
func (device *Device) RoutineTUNEventReader() {
|
2018-02-11 23:26:54 +01:00
|
|
|
setUp := false
|
2021-01-22 23:11:17 +01:00
|
|
|
device.debugf("Routine: event worker - started")
|
2018-05-16 22:20:15 +02:00
|
|
|
|
2017-08-22 14:57:32 +02:00
|
|
|
for event := range device.tun.device.Events() {
|
2019-06-10 23:33:40 +02:00
|
|
|
if event&tun.EventMTUUpdate != 0 {
|
2017-08-22 14:57:32 +02:00
|
|
|
mtu, err := device.tun.device.MTU()
|
|
|
|
old := atomic.LoadInt32(&device.tun.mtu)
|
|
|
|
if err != nil {
|
2021-01-22 23:11:17 +01:00
|
|
|
device.errorf("Failed to load updated MTU of device: %v", err)
|
2017-08-22 14:57:32 +02:00
|
|
|
} else if int(old) != mtu {
|
|
|
|
if mtu+MessageTransportSize > MaxMessageSize {
|
2021-01-22 23:11:17 +01:00
|
|
|
device.infof("MTU updated: %v (too large)", mtu)
|
2017-08-22 14:57:32 +02:00
|
|
|
} else {
|
2021-01-22 23:11:17 +01:00
|
|
|
device.infof("MTU updated: %v", mtu)
|
2017-08-22 14:57:32 +02:00
|
|
|
}
|
2017-08-22 17:22:45 +02:00
|
|
|
atomic.StoreInt32(&device.tun.mtu, int32(mtu))
|
2017-08-22 14:57:32 +02:00
|
|
|
}
|
|
|
|
}
|
|
|
|
|
2019-06-10 23:33:40 +02:00
|
|
|
if event&tun.EventUp != 0 && !setUp {
|
2021-01-22 23:11:17 +01:00
|
|
|
device.infof("Interface set up")
|
2018-02-11 23:26:54 +01:00
|
|
|
setUp = true
|
2017-12-29 17:42:09 +01:00
|
|
|
device.Up()
|
2017-08-22 14:57:32 +02:00
|
|
|
}
|
|
|
|
|
2019-06-10 23:33:40 +02:00
|
|
|
if event&tun.EventDown != 0 && setUp {
|
2021-01-22 23:11:17 +01:00
|
|
|
device.infof("Interface set down")
|
2018-02-11 23:26:54 +01:00
|
|
|
setUp = false
|
2018-01-13 09:00:37 +01:00
|
|
|
device.Down()
|
2017-08-22 14:57:32 +02:00
|
|
|
}
|
|
|
|
}
|
2018-05-16 22:20:15 +02:00
|
|
|
|
2021-01-22 23:11:17 +01:00
|
|
|
device.debugf("Routine: event worker - stopped")
|
2018-05-16 22:20:15 +02:00
|
|
|
device.state.stopping.Done()
|
2017-08-22 14:57:32 +02:00
|
|
|
}
|